Giới thiệu Tin Tức - Dịch vụ Video Khuyến mãi Hỏi đáp Hệ thống cửa hàng Liên hệ Tuyển dụng Tài liệu - Catalog

Danh mục sản phẩm

Ampe kìm AC/DC Fluke 355, 40A/2000A (True Rms)

0 lượt đánh giá

Hãng: Fluke
Tình trạng: Còn hàng
Model: 355

Giá bán:

Liên hệ
Số lượng

Liên hệ để có giá tốt

Ampe kìm AC/DC Fluke 355

Hãng sản xuất : Fluke

Model: 355

Xuất xứ : China

Thông số kỹ thuật:

Electrical specifications

Current measurement dc and ac 10 Hz to 100 Hz

Range : 40 A

 Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A

Range : 400 A

 Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A

Range : 2000 A; 1400 ac rms

 Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A

Crest Factor (50/60 Hz)

Range : 40 A

 Crest Factor* : 2 @ 33 A, 2.4 @ 27 A

Range : 400 A

 Crest Factor* : 2 @ 330 A, 2.4 @ 270 A

Range : 2000 A; 1400 ac rms

 Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A

Current measurement ac 100.1 Hz to 1 kHz

Range : 40 A

 Resolution: 10 mA 
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A

Range : 400 A

 Resolution: 100 mA 
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A

Range : 2000 A; 1400 ac rms

 Resolution: 1 A 
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A

Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz 
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)

Range : 4 V

 Resolution: 1 mV 
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V

Range : 40 V

 Resolution: 10 mV 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V

Range : 400 V

 Resolution: 100 mV 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range : 600 V ac rms

 Resolution: 1 V 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range : 1000 V dc

 Resolution: 1 V 
Accuracy: 1 % rdg + 5 digits

Voltage measurement (355 only) ac 100.1 Hz to 1 kHz 
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)

Range: 4 V

 Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V

Range: 40 V

 Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V

Range: 400 V

 Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range: 600 V ac rms

 Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Ohms measurement (355 only)

Range: 400 Ω

 Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits

Range: 4 kΩ

 Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits

Range: 40 kΩ

 Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits

Range: 400 kΩ

 Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits

Continuity beeper (355 only)

 

 On at ≤ 30 Ω

 

 Off at ≥ 100 Ω

Frequency measurement

Measurement range

 5.0 Hz to 1 kHz

Resolution

 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)

Accuracy – 5.0 Hz to 100 Hz

 0.2 % + 2 counts

Accuracy – 100.1 Hz to 1 kHz

 0.5 % + 5 counts

Trigger level

 Refer to current and voltage tables

 

General specifications

Batteries

 

 Six 1.5 V AA NEDA 15 A or IEC LR6

Battery life (with typical usage, backlight off)

 

 100 hours

Test leads

 

 Rated to 1000 V

Weight

 

 .814 kg (1.8 lb)

Jaw size

 

 58 mm (2.28 in)

Dimensions (LxWxD)

 

 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)

Safety rating

 

 IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

 

Environmental specifications

Operating temperature

 

 32 °F to + 122 °F (0 °C to +50 °C)

Storage temperature

 

 -4 °F to 140 °F (-20 °C to +60 °C)

Operating humidity

 

 0 to 95 % (non-condensing)

Operating altitude

 

 2000 m

Storage altitude

 

 10,000 m

IP rating

 

 42 (indoor use only)

Drop test requirements

 

 1 m

EMI, RFI, EMC

 

 FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325

Temperature coefficients

Current:

 0.1 % of reading per °C outside 22 °C to 24 °C

Voltage:

 0.1 % of reading per °C outside 22 °C to 24 °C

 

 

Xem thêm
Hãng sản xuất Fluke
Xuất xứ China

Video

Video sản phẩm đang được cập nhật.....

Download

chưa có link download

Bình luận về sản phẩm

Tag:

Phụ kiện sản phẩm

Sản phẩm nổi bật

Tin tức liên quan

Sản phẩm cùng thương hiệu

Sản phẩm đã xem

Thước đo, thước dây, thước thép, thước sợi thủy tinh yamayo nhật bản Thiết bị kỹ thuật - đo lường Thiết bị kỹ thuật - đo lường Thiết bị kiểm tra DeFelsko Thiết bị đo độ ẩm Aqua Boy